$ 771.27
1-2 weeks delivery time
-
+
The Webasto WBCL151004B flow control valve assembly is built for Slimline and Low Profile A-Series air handlers and operates as a 3/2-way valve to bypass chilled water around the heat exchanger when required. Screw connections fit all A-Series units without soldering, and the electrical connection is designed for straightforward integration with A-Series electronics. The included 90° elbows support an extra-flat installation, while smart flow control helps route chilled water only where cooling or heating is needed, reducing unwanted heating, condensate build-up, and mold risk on inactive air handlers. EAN 4054037266379; weight 0.31 kg; former part number WBCL151004A.
- Description
- Ask a Question
-
Webasto WBCL151004B Motorized Flow Valve Kit for A-Series Slimline and Low Profile Units
The Webasto WBCL151004B is a dedicated flow control valve for Webasto A-Series air handlers in Slimline and Low Profile configurations. Acting as a 3/2-way valve, it enables chilled water to bypass the heat exchanger when needed, improving comfort management onboard and helping avoid unwanted side effects when an air handler is switched off.
Compatibility
- Slimline A-Series air handlers
- Low Profile A-Series air handlers
- All A-Series units (screw connection, no soldering required)
Technical Specifications
Part Number WBCL151004B Former Part Number WBCL151004A EAN 4054037266379 Weight 0.31 kg Valve Function 3/2-way valve
Product Details
- Purpose: Controls chilled-water flow and allows bypass of the A-Series heat exchanger as needed
- Connections: Screw connection to A-Series units (no soldering needed)
- Electrical Integration: Easy electrical connection to A-Series electronics
- Installation: 90° elbows included in the Slimline and Low Profile kit for an extra-flat installation
- Kit Identification: Motor valve kit for Slimline and Low Profile A-Series
- Spare Parts Note: A-Series Slimline and Low Profile valve spare parts
Features
- Directs chilled water only to cabins with cooling or heating demand
- Helps prevent inadvertent heating when the air handler is switched off (no chimney effect)
- Helps prevent condensate build-up and mold on heat exchangers of air handlers that are switched off
- Continuous blower operation is possible to reduce noise variations in cabins
- Super-silent operation supported by flexible vibration isolation mounts and larger ducts to reduce airspeed noise
- Oversized heat exchanger tested under tropical conditions
-