Price incl. 19% VAT
- 14 kW
- 6,5 kW
- Description
- Ask a Question
-
The standard package for all VETUS diesel generators includes:
- Exhaust system
- Water intake system
VETUS diesel generators meet electromagnetic compatibility requirements when used with sound-insulating enclosures.
Specifications:
For models GLS6.5, GLS7.5, GLS14, and GLS17:
- Voltage error: ± 3.5%
- Security Class: IP44
- Overload capacity (2 seconds): 1.5 times rated current
- Max. ambient temperature: 40°C
- Max. water temperature: 30°C
- Noise level with sound insulation casing: 57 dB
- Max. constant inclination angle: Along the vessel 15°, Across the vessel 25°
For models GLS25 and GLS30:
- Voltage error: ± 2%
- Security Class: IP44
- Overload capacity (2 seconds): 1.5 times rated current
- Max. ambient temperature: 40°C
- Max. water temperature: 30°C
- Noise level with sound insulation casing: 57 dB
- Max. constant inclination angle: Along the vessel 15°, Across the vessel 25°
Two generator units come equipped with a power take-off shaft (P.T.O.) featuring an SAE-B flange. These units offer the option to install a hydraulic pump with a 13-spline shaft with a pitch of 16/32.
GLS Type 14: Suitable for adjustable plunger pump capacity of 0 - 30 cm³.
GLS Type 25: Suitable for adjustable plunger pump capacity of 0 - 30 cm³ or 0 - 45 cm³.
These units use an adjustable plunger pump with pressure/flow control, making them versatile power modules that can generate both electrical and hydraulic energy simultaneously. However, it's essential to note that due to limited engine power when operating the hydraulic pump, there may be instances of insufficient electrical energy. In such cases, automatic disconnection of electricity consumers will occur to prevent overload. To mitigate this, the capacity and operating pressure of the hydraulic pump can be limited.
Applications:
- If your vessel relies on a single main engine, especially during mooring operations where maximum thruster capacity is crucial, the main engine operates at low speeds. This may not provide sufficient power to the hydraulic pump, but the generator unit constantly runs at 1500 rpm, ensuring the needed capacity for thrusters.
- In vessels equipped with a hydraulic emergency propulsion system.
Dimensions of Vetus diesel generators:SKU
GLS6.5/7.5 GLS14/17 GLS25/30 A 920 mm 1120 mm 1360 mm B 390 mm 645 mm 785 mm C 220 mm 130 mm 150 mm D 585 mm 585 mm 700 mm E 555 mm 555 mm 670 mm F 630 mm 630 mm 730 mm -