Price incl. 19% VAT
- 105 kgf
- 130 kgf
- 160 kgf
- 220 kgf
- 12V
- 24V
- Description
- Ask a Question
-
For over thirty years, Vetus has been a pioneer in introducing thrusters to the pleasure and small commercial fleet market. The installation of a bow thruster has become essential for ensuring the maneuverability of vessels. To address the need for longer continuous operation, Vetus has introduced a line of thrusters with extended run time.
Using a thruster is not only convenient but, in many cases, essential for safe mooring and maneuvering in tight spaces, not only for amateurs but even for professionals. The traditional limitation of existing thrusters is their continuous operation time, typically around 2 to 5 minutes per hour. This may be insufficient, especially for amateur boaters operating their own or rented vessels.
The new Vetus Heavy Duty Thrusters with Extended Run Time provide a minimum of 7 minutes of continuous operation and, in many cases, can run without overheating for up to 10 minutes. This extended run time ensures that you have the maneuverability you need, even in challenging conditions.
Vetus DE thrusters with extended continuous time:
Vetus DE thruster dimensions:SKU
Uptime
Resistance Voltage
Ø Tunnelya BOW954DE 10 minutes
105 kgs 24V 185 mm BOW1254DE 10 minutes
130 kgs 24V 250 mm BOW1604DE 10 minen 160 kgs 24V 250 mm BOW2204DE 7 minutes
220 kgs 24V 300 mm
Vetus DE PC Specifications:SKU
A B C D min/max
E OF G min OH BOW95DE 222 mm 492 mm 77 mm 370/740 mm 240 mm 185 mm 185 mm 185 mm BOW125DE 222 mm 523 mm 108 mm 500/1000 mm 240 mm 185 mm 250 mm 259 mm BOW160DE 247 mm 600 mm 108 mm 500/1000 mm 258 mm 212 mm 250 mm 250 mm BOW220DE 247 mm 627 mm 136 mm 600/1200 mm 258 mm 212 mm 300 mm 300 mm
Specifications
BOW95DE BOW125DE BOW160DE BOW220DE Stop, N (kGs)
1050 (105) 1300 (130) 1600 (160) 2200 (220) Power, kW (hp)
5,7 (8) 5,7 (8) 7 (9,5) 11 (15) Reversible D.C. electric motor
da da da da Tunnel diameter (internal), mm
185 250 250 300 Weight without tunnel in package, kg
34 41 62 82 Unpacked tunnel weight, kg
30,7 35,8 55 68 D.C. voltage
24V 24V 24V 24V Current Consumption, A.
350 460 450 720 Continuous operation time, max., min.
10 10 10 7 Continuous operation time per hour, max., min.
10 10 10 7 Fuse, "slow blow," A
355 500 425 675 Battery 12 V D.C., min. A-hour/max. A-hour @ 24B
248/496 308/616 280/560 325/650 BATTERY cables, length (-) + (+), m/mm2
0-21/70 0-20/95 0-29/120 0-21/150 Battery Switch, BATSW/BPMAIN
600/24 600/24 600/24 --- -