Price incl. 19% VAT
- 120A
- 125A with panel DU
- 12V
- 24V
- Description
- Ask a Question
-
- Voltage drop alarm
- Lighting battery relay
- Starter battery charger and CP battery charger (up to 3A charging current with a charger/inverter)
- Three-channel battery separator with minimal voltage drop
The control unit includes a relay that automatically disconnects the household network battery from the load before it can fully discharge, significantly extending battery life.
Specifications:
- Suitable for 12V or 24V systems
- Three-channel battery separator
- Maximum charging current of 125A
- Relay (70A) for lighting network battery
- Automatic shutdown of lighting network battery when voltage is too low
- Trip voltage: 10.5 volts (for 12V systems), 22 volts (for 24V systems) with a one-minute delay
- Switching voltage: 11.5 volts (for 12V systems), 23.5 volts (for 24V systems)
- Unit dimensions (D x W x H): 220mm x 87mm x 133mm
- Weight: 1.7 kg
The control unit includes a remote control panel with a 3-digit LCD screen, providing precise voltage monitoring (accuracy of 0.1V) for one of the three batteries (household network, CP, starter). An intermittent audible signal alerts you to voltage drops below a certain level. You can select the battery, control the household network relay, and more from the panel. The panel connects to the monitor using a thin UTP cable.
Remote Control Panel Specifications:
- 3-digit LCD screen, accuracy: 0.1V
- Indications: panel on/off, alarm, relay, "generator recharge," selected battery
- Buttons for: on/off panel, on/off alarm, on/off local network via relay, battery selection
- Panel dimensions: 161mm x 99mm
- Cut dimensions: 128mm x 76mm
If your vessel has dual propulsion with two DC generators, you can control two monitoring units from a single panel by adding an additional control unit and connecting cable. Each panel can indicate one of the generators, while all other functions remain fully operational.
-