Whisper Power 60201315 - WPC 12 V / 3000 VA - 160 A
Overview
The Whisper Power 60201315 is a robust inverter and battery charger specifically engineered to meet high power demands in various applications. This unit combines efficiency and reliability, offering a pure sine wave output that ensures compatibility with sensitive electronic devices. With its advanced protection features and user-friendly operation, it is the ideal choice for users seeking dependable power solutions.
Technical Specifications
Nominal Battery Voltage: 12 VDC
Continuous Power at 25°C: 2500 VA
Power (30 min) at 25°C: 3000 VA
Power (5 sec) at 25°C: 7500 VA
Maximum Load: Up to short-circuit (fully protected)
Maximum Asymmetric Load: Up to continuous power
Load Detection (Stand-by): 2 to 25 W (AES) Automatic Enable System
Power Factor: 0.1 - 1
Efficiency (@ Full Load): 93%
Consumption: OFF: 1.8 W, Stand-by: 2.1 W, ON: 14 W
Output Voltage: Pure sine wave 230 VAC (+/- 2%)
Output Frequency: 50 Hz / 60 Hz (1) +/- 0.05% (crystal controlled)
Harmonic Distortion (Voltage): < 2% THD
Overload and Short-Circuit Protection: Automatic disconnection with 3-time restart attempt
Overheat Protection: Warning before shut-off with automatic restart
Battery Charger Specifications
Charge Characteristic: 6-step Bulk - Absorption - Floating - Equalization - Reduced Floating - Periodic Absorption. All steps, thresholds, and return amps are fully adjustable.
Maximum Charging Current: 160 A
Temperature Compensation: With Whisper temperature sensor WPC-BTS
Power Factor Correction (PFC): EN 61000-3-2
Input Voltage Range: 150 to 250 VAC
Input Frequency Range: 45 to 65 Hz
Input Current Max (Transfer Relay) / Output Current Max: 50 A / 56 A
Transfer Time: < 15 ms
Main Specifications
Weight: 34 kg
Dimensions (H x W x D): 500 x 300 x 230 mm
Protection Degree: IP21
Color: RAL 9003
Conformity: Directive EMC 2004/108/EC: EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2, 62040-2. Low Voltage Directive 2006/95/EC: EN 62040-1-1, EN 50091-2, EN 60950-1
Operating Temperature Range: -20..+40°C, derating to 55°C
Relative Humidity (Operational): 95% without condensation
Ventilation: Forced from 45°C
Warranty: 2 years
Acoustic Level: < 40 dB / < 45 dB (without / with ventilation)
Accessories
- 60201032: WPC-BUS cable 15 meter
- 60201030: WPC auto start cable 15 meter
- 60201021: WPC 24 VDC - 5 A slave charger (optional second slave charger to be 'built in' WPC)
- 40280101: Touch panel screen full color 7”
-