Whisper Power 60201082 - WPC-BSI 500 Battery Status Interface
The Whisper Power 60201082 WPC-BSI 500 Battery Status Interface is an essential tool for monitoring and managing the state of charge in energy systems with batteries. It offers highly precise measurements and an efficient algorithm to calculate the battery's state of charge accurately, which is crucial for safe and effective operation. The WPC-PSCP and WPC-RCC panels provide comprehensive data logging, display features, and settings customization, including graphical displays of charge history. This interface helps avoid sudden battery depletion by providing real-time data on battery status.
Key values that can be displayed include:
- State of charge (percentage)
- Battery voltage
- Current
- Time remaining
- Throughput energy
- Battery temperature
The BSI 500 ensures precise energy monitoring of battery banks, allowing users to monitor amperes consumed and time remaining before depletion, enhancing reliability and longevity of battery life.
Dimensions & Weight
Dimensions (mm): 110.5 x 75 x 26
Weight (Kg): 0.9Technical Specifications
Supply voltage range: 7..85 VDC
Supply current: 3mA @ 48VDC
Input voltage range: 7..85 VDC
Shunt measurement input range: ±195 mV
RMS continuous current @ 25 °C: ±500 A
Maximum measurable peak current: ±1950 A
Voltage measurement accuracy: 0.3 %
Current measurement accuracy: 0.5 %
Battery capacity: 20..20000 AhReadout Resolutions
- Current (A) and capacity (Ah) (1..10): ±0.01
- Current (A) and capacity (Ah) (10..100): ±0.1
- Current (A) and capacity (Ah) (100..9999): ±1
- State of charge: ±0.1 %
- Temperature: ±0.1 °C
- Time to go: ±1 sec.
Readout Information
Battery voltage, current, state of charge, power used, time to go, battery temperature, relative capacity, historical Ah data, total kAh charged, total kAh discharged, total charge time in Ah and hours.
General Specifications
Operating temperature: -20..+40 °C
Protection degree: IP20
Conformity: LVD 2006/95/EC, EMC 2004/108/EC, RoHS 2002/95/ECEN 60950:2005, EN 61000-6-2:2005, EN 61000-6-3:2007 -