The Victron Lynx Class-T Power In (M10) is a modular 1000A-rated DC busbar with integrated fuse mounts for two Class-T fuses (225–400A, not included). Designed for use with 12V, 24V, and 48V systems, it allows safe and scalable battery input integration using M10 busbars and 3/8" fuse terminals. The unit supports two lithium battery strings, includes a ground terminal, and features an ABS housing (279 x 169 x 97 mm) with IP20 protection. Ideal for high-current DC systems using Victron Smart BMS or Distributor modules.
- Description
- Ask a Question
-
Victron Energy Lynx Class-T Power In (M10) – 1000A DC Busbar with Dual Fuse Slots
The Lynx Class-T Power In (M10) is a high-performance DC input busbar system from Victron Energy, built to safely integrate lithium battery strings in modular energy setups. It provides robust current handling, built-in fuse protection, and seamless integration with other M10 Lynx components such as Smart BMS and Distributor modules.
Main Features
- Continuous current rating: 1000A @ 12/24/48V systems
- Supports up to two Class-T fuses (225A to 400A, sold separately)
- Dual high-current battery inputs with internal tinned copper busbars
- Positive and negative busbars with M10 connection terminals
- Dedicated ground terminal
- Modular M10 interconnection with other Lynx components
Technical Specifications
Electrical Voltage range 9 – 60 VDC Continuous current rating 1000A Fuse support 2x Class-T (225–400A, 3/8” bolts) Fuse connection bolts 3/8" (M10 for SN HQxxxx) Mechanical Busbar connection type M10 Enclosure material ABS Enclosure dimensions (H × W × D) 279 × 169 × 97 mm Unit weight 2.1 kg Busbar material Tinned copper Busbar dimensions 8 × 30 mm Environmental Operating temperature -40°C to +60°C Storage temperature -40°C to +65°C Humidity Max. 95% (non-condensing) Protection class IP20
Installation Notes
- Compatible only with M10 Lynx system modules
- Mountable in any orientation; includes labels for upside-down mounting
- Fuses must be tightened to 33Nm (3/8" nuts)
- M10 bolts for battery and busbar connections (33Nm torque)
- Use cable lugs sized up to 120mm² or 3/8"-4/0 AWG