1-2 weeks delivery time Price incl. 19% VAT Designed for navigation in extreme conditions, ISO9650-1 certified and cataloged in class A (activation at -15 ∞ C) is built with double insulation floor with automatic opening arch and external light 4.3 cd. It is equipped with large containment pockets for safety and survival equipment, a large floating anchor and a ballasted reversible ladder that allows easy and comfortable ascent from the sea. There are two types of survival equipment available depending on the expected time that the victim can spend in the raft waiting for the rescue: the standard one, without drinking water and food, if the rescue forces are expected within 24 hours of stay at sea, the one emergency, which also includes water and food, if the rescue forces are expected beyond 24 hours at sea. |
€ 4.562,66
-
+
|
1-2 weeks delivery time Price incl. 19% VAT Pair of PVC battery terminal cover. |
€ 5,16
-
+
|
1-2 weeks delivery time Price incl. 19% VAT Black varnished light alloy panelwith battery charge test.Dims. mm. 64x83. |
€ 18,76
-
+
|
1-2 weeks delivery time Price incl. 19% VAT Light alloy panel painted blackwith digital test charge 2 batteries.Dims. mm. 64x83. |
€ 27,65
-
+
|
1-2 weeks delivery time Price incl. 19% VAT 12/24 Vdc battery test panel with 3-digit easy-to-read voltmeter and selection deviator. It allows you to check the status of 2 separate batteries or two separate battery packs.Fixing with 4 front screws.Dim. mm. 60x100 |
€ 25,34
-
+
|
1-2 weeks delivery time Price incl. 19% VAT Plastic panel with 3 digit digital voltmeter, easy to read to check the battery voltage or 12 / 24vdc battery pack. Magnetothermic protection. Fixing with 4 front screws hidden by a finishing plate. Dim. mm. 60x100 |
€ 16,35
-
+
|
1-2 weeks delivery time Price incl. 19% VAT Positive and negative battery terminals brass mounting on the axle, with 4 outlets, for connecting various devices simultaneously. |
€ 11,97
-
+
|
1-2 weeks delivery time Price incl. 19% VAT RELiON lithium batteries provide more power than lead-acid batteries, increase performance and weigh half as much.They can be charged quickly, but a slower charging rate of e.g. 2-5 hours is recommended.Unlike other batteries, leaving them partially discharged does not reduce their life or long-term performance. Their charging capacity is about 25-50% higher than other models, which ensures prolonged use of the equipment and avoids voltage drops as the charge decreases.Maintenance-free, they last up to 10 times longer than their lead-acid counterparts, while retaining 80% of capacity after 2000 cycles. They are more temperature tolerant, being able to operate safely up to 65∞C and offer higher performance at low temperatures.Series or parallel connectionsWhen connecting batteries in series or parallel, please observe the following guidelines:(1) Before putting them into service, ensure that each battery does not exceed 50mV (0.05V). This will minimise the possibility of imbalance between the batteries. If they become unbalanced, the voltage of any battery is >50mV (0.05V), relative to another in the set, each battery must be individually charged to rebalance. (2) Size the batteries in parallel appropriately: the capacity (rated in hours) when connected in parallel increases by the multiple of the batteries connected (2x, 3x, 4x, etc.). However, the nominal current (discharge and charge) of the batteries in parallel only increases by 75% of the multiple of the connected batteries (1.5x, 2.4x, etc.) (1.5x, 2.25x, 3x, etc.). (3) Batteries connected in series charge better as single batteries. Series charging can cause imbalances and reduce operating time, requiring an occasional individual balancing charge. (4) Please refer to the RELION document on instructions for series and parallel charging.Discharging the LiFePO4 batteryLiFePO4 batteries can be discharged up to 100% of their capacity. However, to optimise performance and prevent the BMS from disconnecting it, it is recommended to limit discharge to 80%. Please refer to the batteryТs data sheet for the continuous and peak discharge rates of the specific model.When to charge the LiFePO4 battery If LiFePO4 batteries are not fully discharged, it is not necessary to charge them after each use, they will not be damaged if left in a partial state of charge (PSOC). They can be charged after each use or when they have been discharged to 80% (20% SOC). If the BMS disconnects the battery due to low voltage, at 100% discharge, remove the load to reconnect the battery circuit and charge immediately. It is recommended to store batteries at 50% state of charge (SOC).Use compatible chargers for lithium batteries, such as ProMariner. When charging from an alternator, check that it is compatible and has the correct charging parameters. |
€ 2.594,63
-
+
|
1-2 weeks delivery time Price incl. 19% VAT RELiON lithium batteries provide more power than lead-acid batteries, increase performance and weigh half as much.They can be charged quickly, but a slower charging rate of e.g. 2-5 hours is recommended.Unlike other batteries, leaving them partially discharged does not reduce their life or long-term performance. Their charging capacity isabout 25-50% higher than other models, which ensures prolonged use of the equipment and avoids voltage drops as the charge decreases.Maintenance-free, they last up to 10 times longer than their lead-acid counterparts, while retaining 80% of capacity after 2000 cycles. They aremore temperature tolerant, being able to operate safely up to 65∞C and offer higher performance at low temperatures.Series or parallel connectionsWhen connecting batteries in series or parallel, please observe the following guidelines:(1) Before putting them into service, ensure that each battery does not exceed 50mV (0.05V). This will minimise the possibility of imbalancebetween the batteries. If they become unbalanced, the voltage of any battery is >50mV (0.05V), relative to another in the set, each battery mustbe individually charged to rebalance. (2) Size the batteries in parallel appropriately: the capacity (rated in hours) when connected in parallelincreases by the multiple of the batteries connected (2x, 3x, 4x, etc.). However, the nominal current (discharge and charge) of the batteries inparallel only increases by 75% of the multiple of the connected batteries (1.5x, 2.4x, etc.) (1.5x, 2.25x, 3x, etc.). (3) Batteries connected in seriescharge better as single batteries. Series charging can cause imbalances and reduce operating time, requiring an occasional individual balancingcharge. (4) Please refer to the RELION document on instructions for series and parallel charging.Discharging the LiFePO4 batteryLiFePO4 batteries can be discharged up to 100% of their capacity. However, to optimise performance and prevent the BMS from disconnectingit, it is recommended to limit discharge to 80%. Please refer to the batteryТs data sheet for the continuous and peak discharge rates of thespecific model.When to charge the LiFePO4 batteryIf LiFePO4 batteries are not fully discharged, it is not necessary to charge them after each use, they will not be damaged if left in a partial stateof charge (PSOC). They can be charged after each use or when they have been discharged to 80% (20% SOC). If the BMS disconnects thebattery due to low voltage, at 100% discharge, remove the load to reconnect the battery circuit and charge immediately. It is recommended tostore batteries at 50% state of charge (SOC).Use compatible chargers for lithium batteries, such as ProMariner. When charging from an alternator, check that it is compatible andhas the correct charging parameters. |
€ 1.334,34
-
+
|
1-2 weeks delivery time Price incl. 19% VAT RELiON lithium batteries provide more power than lead-acid batteries, increase performance and weigh half as much.They can be charged quickly, but a slower charging rate of e.g. 2-5 hours is recommended.Unlike other batteries, leaving them partially discharged does not reduce their life or long-term performance. Their charging capacity isabout 25-50% higher than other models, which ensures prolonged use of the equipment and avoids voltage drops as the charge decreases.Maintenance-free, they last up to 10 times longer than their lead-acid counterparts, while retaining 80% of capacity after 2000 cycles. They aremore temperature tolerant, being able to operate safely up to 65∞C and offer higher performance at low temperatures.Series or parallel connectionsWhen connecting batteries in series or parallel, please observe the following guidelines:(1) Before putting them into service, ensure that each battery does not exceed 50mV (0.05V). This will minimise the possibility of imbalancebetween the batteries. If they become unbalanced, the voltage of any battery is >50mV (0.05V), relative to another in the set, each battery mustbe individually charged to rebalance. (2) Size the batteries in parallel appropriately: the capacity (rated in hours) when connected in parallelincreases by the multiple of the batteries connected (2x, 3x, 4x, etc.). However, the nominal current (discharge and charge) of the batteries inparallel only increases by 75% of the multiple of the connected batteries (1.5x, 2.4x, etc.) (1.5x, 2.25x, 3x, etc.). (3) Batteries connected in seriescharge better as single batteries. Series charging can cause imbalances and reduce operating time, requiring an occasional individual balancingcharge. (4) Please refer to the RELION document on instructions for series and parallel charging.Discharging the LiFePO4 batteryLiFePO4 batteries can be discharged up to 100% of their capacity. However, to optimise performance and prevent the BMS from disconnectingit, it is recommended to limit discharge to 80%. Please refer to the batteryТs data sheet for the continuous and peak discharge rates of thespecific model.When to charge the LiFePO4 batteryIf LiFePO4 batteries are not fully discharged, it is not necessary to charge them after each use, they will not be damaged if left in a partial stateof charge (PSOC). They can be charged after each use or when they have been discharged to 80% (20% SOC). If the BMS disconnects thebattery due to low voltage, at 100% discharge, remove the load to reconnect the battery circuit and charge immediately. It is recommended tostore batteries at 50% state of charge (SOC).Use compatible chargers for lithium batteries, such as ProMariner. When charging from an alternator, check that it is compatible andhas the correct charging parameters. |
€ 1.334,34
-
+
|
1-2 weeks delivery time Price incl. 19% VAT RELiON lithium batteries provide more power than lead-acid batteries, increase performance and weigh half as much.They can be charged quickly, but a slower charging rate of e.g. 2-5 hours is recommended.Unlike other batteries, leaving them partially discharged does not reduce their life or long-term performance. Their charging capacity isabout 25-50% higher than other models, which ensures prolonged use of the equipment and avoids voltage drops as the charge decreases.Maintenance-free, they last up to 10 times longer than their lead-acid counterparts, while retaining 80% of capacity after 2000 cycles. They aremore temperature tolerant, being able to operate safely up to 65∞C and offer higher performance at low temperatures.Series or parallel connectionsWhen connecting batteries in series or parallel, please observe the following guidelines:(1) Before putting them into service, ensure that each battery does not exceed 50mV (0.05V). This will minimise the possibility of imbalancebetween the batteries. If they become unbalanced, the voltage of any battery is >50mV (0.05V), relative to another in the set, each battery mustbe individually charged to rebalance. (2) Size the batteries in parallel appropriately: the capacity (rated in hours) when connected in parallelincreases by the multiple of the batteries connected (2x, 3x, 4x, etc.). However, the nominal current (discharge and charge) of the batteries inparallel only increases by 75% of the multiple of the connected batteries (1.5x, 2.4x, etc.) (1.5x, 2.25x, 3x, etc.). (3) Batteries connected in seriescharge better as single batteries. Series charging can cause imbalances and reduce operating time, requiring an occasional individual balancingcharge. (4) Please refer to the RELION document on instructions for series and parallel charging.Discharging the LiFePO4 batteryLiFePO4 batteries can be discharged up to 100% of their capacity. However, to optimise performance and prevent the BMS from disconnectingit, it is recommended to limit discharge to 80%. Please refer to the batteryТs data sheet for the continuous and peak discharge rates of thespecific model.When to charge the LiFePO4 batteryIf LiFePO4 batteries are not fully discharged, it is not necessary to charge them after each use, they will not be damaged if left in a partial stateof charge (PSOC). They can be charged after each use or when they have been discharged to 80% (20% SOC). If the BMS disconnects thebattery due to low voltage, at 100% discharge, remove the load to reconnect the battery circuit and charge immediately. It is recommended tostore batteries at 50% state of charge (SOC).Use compatible chargers for lithium batteries, such as ProMariner. When charging from an alternator, check that it is compatible andhas the correct charging parameters. |
€ 1.037,82
-
+
|
1-2 weeks delivery time Price incl. 19% VAT RELiON lithium batteries provide more power than lead-acid batteries, increase performance and weigh half as much.They can be charged quickly, but a slower charging rate of e.g. 2-5 hours is recommended.Unlike other batteries, leaving them partially discharged does not reduce their life or long-term performance. Their charging capacity isabout 25-50% higher than other models, which ensures prolonged use of the equipment and avoids voltage drops as the charge decreases.Maintenance-free, they last up to 10 times longer than their lead-acid counterparts, while retaining 80% of capacity after 2000 cycles. They aremore temperature tolerant, being able to operate safely up to 65∞C and offer higher performance at low temperatures.Series or parallel connectionsWhen connecting batteries in series or parallel, please observe the following guidelines:(1) Before putting them into service, ensure that each battery does not exceed 50mV (0.05V). This will minimise the possibility of imbalancebetween the batteries. If they become unbalanced, the voltage of any battery is >50mV (0.05V), relative to another in the set, each battery mustbe individually charged to rebalance. (2) Size the batteries in parallel appropriately: the capacity (rated in hours) when connected in parallelincreases by the multiple of the batteries connected (2x, 3x, 4x, etc.). However, the nominal current (discharge and charge) of the batteries inparallel only increases by 75% of the multiple of the connected batteries (1.5x, 2.4x, etc.) (1.5x, 2.25x, 3x, etc.). (3) Batteries connected in seriescharge better as single batteries. Series charging can cause imbalances and reduce operating time, requiring an occasional individual balancingcharge. (4) Please refer to the RELION document on instructions for series and parallel charging.Discharging the LiFePO4 batteryLiFePO4 batteries can be discharged up to 100% of their capacity. However, to optimise performance and prevent the BMS from disconnectingit, it is recommended to limit discharge to 80%. Please refer to the batteryТs data sheet for the continuous and peak discharge rates of thespecific model.When to charge the LiFePO4 batteryIf LiFePO4 batteries are not fully discharged, it is not necessary to charge them after each use, they will not be damaged if left in a partial stateof charge (PSOC). They can be charged after each use or when they have been discharged to 80% (20% SOC). If the BMS disconnects thebattery due to low voltage, at 100% discharge, remove the load to reconnect the battery circuit and charge immediately. It is recommended tostore batteries at 50% state of charge (SOC).Use compatible chargers for lithium batteries, such as ProMariner. When charging from an alternator, check that it is compatible andhas the correct charging parameters. |
€ 2.594,63
-
+
|
1-2 weeks delivery time Price incl. 19% VAT RELiON lithium batteries provide more power than lead-acid batteries, increase performance and weigh half as much.They can be charged quickly, but a slower charging rate of e.g. 2-5 hours is recommended.Unlike other batteries, leaving them partially discharged does not reduce their life or long-term performance. Their charging capacity isabout 25-50% higher than other models, which ensures prolonged use of the equipment and avoids voltage drops as the charge decreases.Maintenance-free, they last up to 10 times longer than their lead-acid counterparts, while retaining 80% of capacity after 2000 cycles. They aremore temperature tolerant, being able to operate safely up to 65∞C and offer higher performance at low temperatures.Series or parallel connectionsWhen connecting batteries in series or parallel, please observe the following guidelines:(1) Before putting them into service, ensure that each battery does not exceed 50mV (0.05V). This will minimise the possibility of imbalancebetween the batteries. If they become unbalanced, the voltage of any battery is >50mV (0.05V), relative to another in the set, each battery mustbe individually charged to rebalance. (2) Size the batteries in parallel appropriately: the capacity (rated in hours) when connected in parallelincreases by the multiple of the batteries connected (2x, 3x, 4x, etc.). However, the nominal current (discharge and charge) of the batteries inparallel only increases by 75% of the multiple of the connected batteries (1.5x, 2.4x, etc.) (1.5x, 2.25x, 3x, etc.). (3) Batteries connected in seriescharge better as single batteries. Series charging can cause imbalances and reduce operating time, requiring an occasional individual balancingcharge. (4) Please refer to the RELION document on instructions for series and parallel charging.Discharging the LiFePO4 batteryLiFePO4 batteries can be discharged up to 100% of their capacity. However, to optimise performance and prevent the BMS from disconnectingit, it is recommended to limit discharge to 80%. Please refer to the batteryТs data sheet for the continuous and peak discharge rates of thespecific model.When to charge the LiFePO4 batteryIf LiFePO4 batteries are not fully discharged, it is not necessary to charge them after each use, they will not be damaged if left in a partial stateof charge (PSOC). They can be charged after each use or when they have been discharged to 80% (20% SOC). If the BMS disconnects thebattery due to low voltage, at 100% discharge, remove the load to reconnect the battery circuit and charge immediately. It is recommended tostore batteries at 50% state of charge (SOC).Use compatible chargers for lithium batteries, such as ProMariner. When charging from an alternator, check that it is compatible andhas the correct charging parameters. |
€ 1.378,82
-
+
|
1-2 weeks delivery time Price incl. 19% VAT RELiON lithium batteries provide more power than lead-acid batteries, increase performance and weigh half as much.They can be charged quickly, but a slower charging rate of e.g. 2-5 hours is recommended.Unlike other batteries, leaving them partially discharged does not reduce their life or long-term performance. Their charging capacity isabout 25-50% higher than other models, which ensures prolonged use of the equipment and avoids voltage drops as the charge decreases.Maintenance-free, they last up to 10 times longer than their lead-acid counterparts, while retaining 80% of capacity after 2000 cycles. They aremore temperature tolerant, being able to operate safely up to 65∞C and offer higher performance at low temperatures.Series or parallel connectionsWhen connecting batteries in series or parallel, please observe the following guidelines:(1) Before putting them into service, ensure that each battery does not exceed 50mV (0.05V). This will minimise the possibility of imbalancebetween the batteries. If they become unbalanced, the voltage of any battery is >50mV (0.05V), relative to another in the set, each battery mustbe individually charged to rebalance. (2) Size the batteries in parallel appropriately: the capacity (rated in hours) when connected in parallelincreases by the multiple of the batteries connected (2x, 3x, 4x, etc.). However, the nominal current (discharge and charge) of the batteries inparallel only increases by 75% of the multiple of the connected batteries (1.5x, 2.4x, etc.) (1.5x, 2.25x, 3x, etc.). (3) Batteries connected in seriescharge better as single batteries. Series charging can cause imbalances and reduce operating time, requiring an occasional individual balancingcharge. (4) Please refer to the RELION document on instructions for series and parallel charging.Discharging the LiFePO4 batteryLiFePO4 batteries can be discharged up to 100% of their capacity. However, to optimise performance and prevent the BMS from disconnectingit, it is recommended to limit discharge to 80%. Please refer to the batteryТs data sheet for the continuous and peak discharge rates of thespecific model.When to charge the LiFePO4 batteryIf LiFePO4 batteries are not fully discharged, it is not necessary to charge them after each use, they will not be damaged if left in a partial stateof charge (PSOC). They can be charged after each use or when they have been discharged to 80% (20% SOC). If the BMS disconnects thebattery due to low voltage, at 100% discharge, remove the load to reconnect the battery circuit and charge immediately. It is recommended tostore batteries at 50% state of charge (SOC).Use compatible chargers for lithium batteries, such as ProMariner. When charging from an alternator, check that it is compatible andhas the correct charging parameters. |
€ 1.482,61
-
+
|
1-2 weeks delivery time Price incl. 19% VAT The RB100-HP is the first battery to be evaluated and approved for use with selected Mercury MarineЃ outboard engines.Only outboards listed here are approved for use with lithium-ion starter batteries. All other Mercury outboards, MerCruiserЃ engines and Mercury Diesel engines are not approved for use with lithium-ion starter batteries.Models:2.1L 75-115hp FourStroke, Pro XSЃ e SeaProЩ3.0L 150hp FourStroke, Pro XS e SeaPro4.6L V8 and 3.4L V6 175-300hp FourStroke, Pro XS, SeaPro e VeradoЃ2.6L L6 200-400hp Pro e Verado7.6L V12 500-600hp SeaPro e Verado |
€ 1.482,61
-
+
|
1-2 weeks delivery time Price incl. 19% VAT Start and services batteries, zero maintenance, reliability in all weather and an extraordinary power for high absorption. Immediately ready to go, longer life, technology CA100. Safety lid with flame arrestor, central degassing. Dim. mm. 242x175x175 |
€ 139,62
-
+
|
1-2 weeks delivery time Price incl. 19% VAT Start and services batteries, zero maintenance, reliability in all weather and an extraordinary power for high absorption. Immediately ready to go, longer life, technology CA100. Safety lid with flame arrestor, central degassing. Dim. mm. 248x175x190 |
€ 136,21
-
+
|
1-2 weeks delivery time Price incl. 19% VAT Start and services batteries, zero maintenance, reliability in all weather and an extraordinary power for high absorption. Immediately ready to go, longer life, technology CA100. Safety lid with flame arrestor, central degassing. Dim. mm. 278x175x190 |
€ 164,84
-
+
|
1-2 weeks delivery time Price incl. 19% VAT Start and services batteries, zero maintenance, reliability in all weather and an extraordinary power for high absorption. Immediately ready to go, longer life, technology CA100. Safety lid with flame arrestor, central degassing. Dim. mm. 353x175x190 |
€ 213,98
-
+
|
1-2 weeks delivery time Price incl. 19% VAT Start and services batteries for professional use CA100 technology, long life, high cyclic stability, maximum power cold start or large-displacement engines, ready to use, zero maintenance, maximum safety thanks to Labyrinth lid, the flame arrestor and the special caps. Dim. mm. 513x189x223 |
€ 330,67
-
+
|